Exit filters series 16Xx:

 

General Specifications:

 

†††††††††††††† Exit impedance in accordance with IEC61000-4-6,ie 150 ohms +60 -45 ohms over the frequency range 30 to 230MHz,and extended to +150 -75 ohms from 230 to 1000MHz.

 

 

Series Specification:

Exit filter16XB  for EMC chambers

16XB††††† High-isolation wide-bandwidth boxed filter

††††††† Manufactured as required for any user-specified flexible cable of up to 5mm outside diameter.

Packaged in a metal box 160 x 100 x 50mmintended to be bolted onto chamber filter plate.

Cable-mounted interface connectors are required but not included in the basic price.

Differential-mode attenuation is less than that of a 4m length of the users cable.

Common-mode attenuation between 150 ohm terminations:

> 40dB from 10 to 500MHz and

>20dB from 150KHz to 1GHz.

 

 

16X2††††† Clamped duct filter

††††††† For up to two user-installed and easily exchangeable cables,one <6.5mm outside diameter and the other <10mm o/d. ††††††† Packaged in a two-part metal duct 610 x 60 x 30mmintended to be bolted onto chamber wall or floor.

††††††† Differential-mode attenuation is that of an 0.61m length of the userís cable.

††††††† Common-mode attenuation between 150 ohm terminations > 20dB from 30 to 1000MHz.

 

16X3††††† Clamped duct filter

††††††† For up to three user-installed and easily exchangeable cables,one <13mm outside diameter and the others <10mm o/d.Packaged in a two-part metal duct 610 x 100 x 35mmintended to be bolted onto chamber wall or floor.

Differential-mode attenuation is that of an 0.61m length of the userís cable.

Common-mode attenuation between 150 ohm terminations > 20dB from 30 to 1000MHz.

 

 

 

In the search for improved quality this specification is subject to change.© and Design rights reserved Richard Marshall Ltd2000. 16X_sp1.doc ††1.0